Arq. bras. oftalmol ; 80(1): 52-56, Jan.-Feb. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-838776

RESUMEN

ABSTRACT We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an organic dye. Inlay implantation occurred under mechanical microkeratome Lasik flaps set for a depth of 120 µm. The patient returned to the clinic 11 years after surgery and reported loss of near-vision acuity. Clinical examination showed the complete absence of pigments in the device and the total loss of the initial effect on near vision, despite normal distance vision. Manifest refraction remained stable during the follow-up period. Scheimpflug images characterized the loss of the small aperture effect on incoming light. Confocal analysis revealed small hyper-reflective round images on the endothelium and no signs of inflammation.


RESUMO Descrevemos um caso de importante despigmentação de início tardio de implante corneano de pequena abertura implantada para compensação de presbiopia. O paciente foi um dos participantes de ensaio clínico destinado a avaliar a segurança e eficácia do AcuFocusTM ACU-10R160, uma película de poliimida de 10 microns de espessura, tingida com um corante orgânico. A implantação ocorreu sob um flap de Lasik criado por microcerátomo mecânico ajustado para profundidade de 120 µm. O caso aqui descrito foi avaliado 11 anos após a cirurgia, relatando diminuição de acuidade de visão para perto. O exame clínico mostrou ausência total de pigmentos no dispositivo e perda total do efeito inicial na visão de perto, apesar da visão normal para distância. A refração manifesta permaneceu estável durante o período de seguimento. As imagens de Scheimpflug caracterizaram a perda do efeito da abertura pequena na luz entrante. A análise de microscopia confocal revelou pequenas imagens hiper-reflexivas redondas sobre o endotélio, sem sinais de inflamação.


Asunto(s)
Humanos , Femenino , Anciano , Presbiopía/cirugía , Prótesis e Implantes , Sustancia Propia/cirugía , Implantación de Prótesis/instrumentación , Queratomileusis por Láser In Situ/instrumentación , Refracción Ocular , Colgajos Quirúrgicos , Agudeza Visual , Implantación de Prótesis/métodos , Queratomileusis por Láser In Situ/métodos
2.
Arq. bras. oftalmol ; 76(6): 335-338, nov.-dez. 2013. graf, tab
Artículo en Portugués | LILACS | ID: lil-701281

RESUMEN

OBJETIVO: Avaliar comparativamente os resultados cirúrgicos, na técnica LASIK, realizando com laser de femtosegundo e microcerátomo mecânico. MÉTODOS: Estudo clínico, prospectivo, comparativo, randomizado e mascarado de 32 olhos (16 pacientes). Cada paciente foi submetido a diferentes técnicas para o LASIK, em um dos olhos foi utilizado o microcerátomo HansatomeTM Bausch & Lomb (grupo microcerátomo) e no outro foi utilizado femtosegundo FEMTO LDV TM Ziemer (grupo femtosegundo). A triagem ocorreu no setor de Cirurgia Refrativa do Hospital de Olhos do Paraná entre 07/2010 e 09/2010. Os critérios de inclusão foram miopia menor que 6,00 D, astigmatismo menor que 3,00 D, menor que 5,00 D de hipermetropia, refração estável, diâmetro corneano menor que 11 mm, descontinuação de lente de contato sete dias antes da avaliação pré-operatória, acuidade visual de no mínimo 20/20 em ambos os olhos. As variáveis analisadas no pré-operatório entre os grupos, femtosegundo e microcerátomo foram: acuidade visual sem correção e com correção, equivalente esférico, aberrações totais de alta ordem, acuidade visual de baixo contraste, preferência do paciente e complicações. RESULTADOS: Todas as variáveis estudadas foram similares nos dois grupos. CONCLUSÃO: Não foi possível observar neste estudo, diferenças significativas entre os grupos analisados.


PURPOSE: To assess LASIK flaps made by femtosecond laser and mechanical microkeratome. METHODS: Clinical, prospective, randomized, masked study of 32 eyes (16 patients). Both eyes of all patients were operated, each patient underwent different techniques for lasik. Microkeratome HansatomeTMBausch & Lomb (group microkeratome) was used in one eye and femtosecond laser Femto LDVTMZiemer (group femtosecond) was used for the fellow eye. Patients were selected from the Refractive Surgery service of the Eye Hospital of Paraná between July 2010 and September 2010. Inclusion criteria were myopia less than 6.00 D, astigmatism less than 3.00 D, hyperopia less than 5.00 D, stable refraction over one year, corneal diameter smaller than 11 mm, discontinuation of contact lenses seven days before the preoperative evaluation, corrected visual acuity of at least 20/20. Eyes were randomly allocated for each technique. The studied variables were: visual acuity with and without correction, residual refractive error, high order aberrations, low contrast visual acuity, complications and subjective patient preference. RESULTS: All studied variables were similar between the two groups. CONCLUSION: We could not demonstrate any difference between the studied groups.


Asunto(s)
Humanos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Colgajos Quirúrgicos/cirugía , Sensibilidad de Contraste , Córnea/cirugía , Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/instrumentación , Periodo Posoperatorio , Estudios Prospectivos , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento , Agudeza Visual
3.
Indian J Ophthalmol ; 2010 Jul; 58(4): 307-312
Artículo en Inglés | IMSEAR | ID: sea-136077

RESUMEN

Purpose: To study the change in ocular aberrations after wavefront optimized (WFO) laser in situ keratomileusis (LASIK) for correction of myopia and to analyze causative factors that may influence them. Materials and Methods: This was a prospective case series. WFO LASIK was performed for the correction of myopia, using the hansatome (Bausch and Lomb) microkeratome to create the flap and the Allegretto laser (Wavelight Technologie) to perform the ablation. The Allegretto wave analyser (Tscherning-type) measured the ocular aberrations prior to LASIK , one month and six months postoperatively. Results: The mean age of the 59 patients included in the study was 25±5.64 years and the mean spherical equivalent of the 117 eyes that underwent LASIK was ‒5.33±1.22 preoperatively and ‒0.21±0.38 postoperatively. Hundred and two eyes of 117 (87%) achieved uncorrected visual acuity (UCVA) of 20/20 or better after WFO LASIK and 104 of 117 eyes (89%) were within ±0.5D of the attempted refractive correction. There was a 1.96-fold increase in total root-mean-square of higher order aberrations. Induced changes in seven of the 22 higher order Zernike terms showed a significant linear correlation with the refractive correction attempted. Larger ablation zones induced less spherical aberration. Conclusion: In spite of an excellent visual outcome, WFO LASIK induces significant higher order aberrations. Large ablation zones reduce the induction of spherical aberration.


Asunto(s)
Adulto , Astigmatismo/cirugía , Diseño de Equipo , Oftalmopatías/epidemiología , Oftalmopatías/etiología , Humanos , Queratomileusis por Láser In Situ/instrumentación , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Selección de Paciente , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adulto Joven
4.
Arq. bras. oftalmol ; 71(2): 221-227, mar.-abr. 2008. graf, tab
Artículo en Inglés | LILACS | ID: lil-483030

RESUMEN

PURPOSE: To evaluate outcome and complications in LASIK with reprocessed blades. METHODS: Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was reprocessed following a clinic protocol, from 1 to 3 times (reprocessed group) and results compared with patients that underwent LASIK with first-use blades (first-use group). RESULTS: Two hundred fifty-one eyes of 135 patients were analyzed (spherical equivalent of -3.69 (D). There was no statistical differences between first-use group and reprocessed blade group regarding intraoperative (5.5 percent vs 8.8 percent), early (50.5 percent vs 49.5 percent) and late complications (33 percent vs 27.5 percent), respectively. Uncorrected visual acuity > 20/20 (68.1 percent vs 66.9 percent), aberrometry analysis (total RMS: 0.62 vs 0.64 µm) and safety (85.7 percent vs 83.1 percent) were similar between groups (p>0.05). CONCLUSION: Reprocessed blades following rigid sterilization protocol may have similar outcomes and complications rates in LASIK surgery compared to first-use blades.


OBJETIVO: Analisar os resultados e complicações do uso de lâminas reprocessadas em cirurgias refrativas com a técnica de LASIK. MÉTODOS: Estudo retrospectivo dos prontuários dos pacientes submetidos a LASIK personalizado durante janeiro de 2004 a junho de 2005. Foram incluídos pacientes que apresentavam relatório transoperatório completo (uso da lâmina) e seguimento mínimo de 1 mês após a cirurgia. O grupo controle foi constituído das lâminas com uso único enquanto no grupo das lâminas reprocessadas poderia variar de 2 a 4 vezes de uso. RESULTADOS: Duzentos e cinqüenta e um olhos de 135 pacientes foram analisados e o equivalente esférico pré-operatório médio foi de -3,69 (D). Não houve diferença significativa entre o número de complicações transoperatórias (5,5 por cento vs 8,8 por cento), pós-operatórias imediatas (50,5 por cento vs 49,5 por cento) e tardias (33 por cento vs 27,5 por cento) entre o grupo de lâminas com uso único e reprocessadas, respectivamente. Os resultados de AV sem correção pós-operatória > 20/20 (68,1 por cento vs 66,9 por cento), aberrometria (RMS total: 0,62 vs 0,64 µm) e segurança (85,7 por cento vs 83,1 por cento) foram similares entre os grupos (p>0,05). CONCLUSÃO: O uso de até 4 vezes da lâmina metálica, seguindo reprocessamento adequado pode apresentar resultados e taxa de complicações semelhantes às cirurgias de LASIK realizadas com lâminas de uso único.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Queratomileusis por Láser In Situ/instrumentación , Instrumentos Quirúrgicos/normas , Equipo Reutilizado , Estudios de Seguimiento , Queratomileusis por Láser In Situ/efectos adversos , Estudios Retrospectivos , Errores de Refracción/etiología , Estadísticas no Paramétricas , Factores de Tiempo
5.
Arq. bras. oftalmol ; 69(6): 845-849, nov.-dez. 2006. ilus, tab
Artículo en Portugués | LILACS | ID: lil-440422

RESUMEN

OBJETIVO: Avaliar e comparar, por microscopia eletrônica de varredura (MEV), a superfície de lâminas cirúrgicas novas e sem uso com lâminas utilizadas consecutivamente no LASIK (Laser in situ keratomileusis). MÉTODOS: Foram utilizadas 25 lâminas cirúrgicas AccuGlide® (Bausch & Lomb, EUA), divididas em 3 grupos: Grupo 1 (controle), cinco lâminas novas e sem uso; Grupo 2, dez lâminas utilizadas duas vezes (cirurgia bilateral simultânea); Grupo 3, dez lâminas utilizadas quatro vezes (duas cirurgias bilaterais simultâneas e consecutivas). Cada lâmina foi analisada em quatro pontos aleatórios, dois centrais e dois periféricos, com aumentos de 50, 350 e 1.000 vezes. RESULTADOS: Irregularidades e deposição de material orgânico na superfície da lâmina foram observados em todas lâminas reutilizadas (Grupos 2 e 3). Além disso, as lâminas do Grupo 3 apresentaram mais irregularidades do que as do Grupo 2 nos pontos centrais (p=0,0094) e periféricos (p=0,0098), bem como em relação ao depósito de material orgânico (p=0,0204 and p=0,0909, respectivamente). Não foram observados presença de material metálico e denteamento da superfície cortante em nenhuma lâmina examinada. CONCLUSÃO: Não foi observada diferença quanto à borda cortante entre lâminas novas e as utilizadas até 4 vezes após LASIK. Por outro lado, observou-se depósito de material orgânico e irregularidades da superfície de todas as lâminas reutilizadas. As implicações clínicas destes achados precisam ser avaliadas devido à possibilidade de estarem relacionados com complicações pós-operatórias interlamelares comumente encontradas no LASIK.


PURPOSE: To evaluate and compare, by scanning electron microscopy (SEM), the sharpness of the edge of brand new surgical blades and consecutively used surgical blades in laser-assisted in situ keratomileusis (LASIK). METHODS: Tewnty-five AccuGlide® (Bausch & Lomb, USA) surgical blades were evaluated, divided in to 3 groups: Group 1 (control), non-used surgical blades; Group 2, ten surgical blades used twice (simultaneous bilateral procedure); Group 3, ten surgical blades used four times (two consecutive simultaneous bilateral procedures). Each blade was analyzed by SEM at four random points, two central and two peripheral points, with magnification of 50x, 350x, and 1,000x. RESULTS: Blade body irregularities and organic material were observed on all used surgical blades (Groups 2 and 3), but not on new surgical blades (Group 1). In addition, Group 3 revealed more irregularities in both central (p=0.0094) and peripheral points (p=0.0098) than Group 2, as well as organic material deposition (p=0.0204 and p=0.0909, respectively). Neither metalic material nor irregularities in the cutting edge of the blade were observed in any group. CONCLUSION: No difference regarding the cutting edge was observed between new and blades reused up to four times, however irregularities and organic material were observed in all reused blades. Reusing blades for LASIK may produce structural changes and its clinical implications need to be evaluated due to the possible relation with interlamellar postoperative complications.


Asunto(s)
Queratomileusis por Láser In Situ/instrumentación , Microscopía Electrónica de Rastreo , Equipo Reutilizado/normas , Estadísticas no Paramétricas , Esterilización , Propiedades de Superficie , Factores de Tiempo
6.
Arq. bras. oftalmol ; 69(4): 561-564, jul.-ago. 2006. ilus
Artículo en Portugués, Inglés | LILACS | ID: lil-435743

RESUMEN

OBJETIVO: Avaliar a qualidade de corte do microcerátomo Masyk® na confecção de lamela corneana pediculada em olhos frescos humanos provenientes de Banco de Olhos. MÉTODOS: Realizou-se estudo prospectivo no "Eye Clinic Day Hospital" (São Paulo, Brasil), com 20 olhos humanos frescos de Banco de Olhos. Utilizou-se o microcerátomo Masyk® para confecção de lamela corneana pediculada. A espessura programada foi 160 µm e o diâmetro programado de 9,5 mm em todos os olhos. As espessuras efetivas das lamelas foram aferidas pelo paquímetro P55, Paradigm, USA e os diâmetros verticais do leito estromal com compasso cirúrgico. RESULTADOS: Não ocorreram complicações durante a utilização do microcerátomo e não foram identificadas lamelas livres, perfuradas ou incompletas. A média das espessuras efetivas foi de 160,34±5,10 µm, com variação entre 149 e 181 µm. A média das medidas dos diâmetros verticais do leito residual foi de 9,64±0,16 mm, com variação entre 9,30 e 9,85 mm. CONCLUSÃO: O corte do microcerátomo Masyk® mostrou-se reprodutível, previsível e seguro em confeccionar lamelas corneanas pediculadas de espessura e diâmetros adequados em olhos humanos frescos de Banco de Olhos.


PURPOSE: To evaluate the cut quality of Masyk® microkeratome in obtaining a corneal flap from human eyes of Eye Banks. METHODS: Prospective study with 20 human eyes from Eye Banks. All flaps were programmed to obtain 160 µm thickness and 9.5 mm diameter. The thicknesses were calculated with P55 pachymeter (Paradigm, USA), and diameter with compass. RESULTS: No complications were observed during the use of the microkeratome. The central corneal thickness average was 160.34±5.10 µm and range from 149 to 181 µm. The vertical diameter average was 9.64±0.16 mm and range from 9.30 to 9.85 mm. CONCLUSION: Masyk® microkeratome showed to be effective for obtention of corneal flap with appropriate thickness and diameter from human corneas of Eye Banks.


Asunto(s)
Humanos , Sustancia Propia/cirugía , Bancos de Ojos , Queratomileusis por Láser In Situ/normas , Colgajos Quirúrgicos , Queratomileusis por Láser In Situ/instrumentación , Estudios Prospectivos , Reproducibilidad de los Resultados
7.
Arq. bras. oftalmol ; 69(2): 151-155, mar.-abr. 2006. ilus
Artículo en Portugués | LILACS | ID: lil-426707

RESUMEN

OBJETIVO: Descrever as características de uma nova câmara anterior artificial e discutir suas vantagens (MALKS®, Loktal, São Paulo, Brasil). MÉTODOS: Análise e descrição das especificações técnicas utilizadas na câmara anterior artificial MALKS® (Micro automated lamellar keratoplasty system). RESULTADOS: O MALKS® é constituído de oito partes: a) câmara artificial; b) anel fixador da córnea; c) porca de travamento do anel fixador; d) trilho e ajustador do diâmetro do disco lamelar; e) aplanadores para aferição e definição do diâmetro do disco lamelar; f) sistema de infusão, que possibilita o controle digital objetivo peroperatório da pressão intracameral; g) microcerátomo automático; h) trépano marcador. CONCLUSÃO: O MALKS® utiliza o mesmo microcerátomo automático desenvolvido para LASIK, possibilita a obtenção de lamelas corneanas de espessura e diâmetro programados, assim como o controle objetivo peroperatório digital da pressão intracameral (PIC). Esta câmara anterior artificial pode ser ferramenta importante tanto para as cirurgias de transplante lamelar superficial quanto endotelial.


Asunto(s)
Humanos , Trasplante de Córnea/instrumentación , Queratomileusis por Láser In Situ/instrumentación , Queratoplastia Penetrante/instrumentación , Recolección de Tejidos y Órganos/instrumentación , Cámara Anterior , Trasplante de Córnea/métodos , Diseño de Equipo , Endotelio Corneal/trasplante , Queratoplastia Penetrante/métodos
8.
Arq. bras. oftalmol ; 69(1): 7-10, jan.-fev. 2006. ilus, tab
Artículo en Portugués | LILACS | ID: lil-420810

RESUMEN

OBJETIVO: Avaliar a qualidade de corte do microceratótomo Masyk® na confeccão de lamela corneana pediculada em olhos porcinos. MÉTODOS: Realizou-se estudo prospectivo na Eye Clinic Day Hospital (São Paulo, Brasil) em 31 olhos porcinos divididos em 2 grupos: 15 olhos nos quais se utilizou a plataforma de 160 æm e anel de succão de 9,5 mm de diâmetro (Grupo 1) e 16 olhos, submetidos à plataforma de 140 æm e anel de succão de 8,5 mm de diâmetro (Grupo 2). As espessuras efetivas das lamelas foram aferidas pelo paquímetro P55 (Paradigm, EUA) e os diâmetros verticais do leito estromal com compasso cirúrgico. RESULTADOS: Não ocorreram complicacões durante a utilizacão do microceratótomo e não foram identificadas lamelas livres, perfuradas ou incompletas. No grupo 1, a média das espessuras efetiva foi de 146,33 n 15,43 æm, com variacão entre 127 e 186 æm. A média das medidas do diâmetro vertical do leito residual foi de 9,39 n 0,26 mm, com variacão entre 8,90 e 9,85 mm. No grupo 2, a média das espessuras efetiva foi de 128,75 n 18,83 æm, com variacão entre 71 e 178 æm. A média das medidas do diâmetro do leito residual foi de 8,27 n 0,20 mm, com variacão entre 7,95 e 8,65 mm. CONCLUSAO: O microceratótomo Masyk® mostrou-se eficaz e seguro em confeccionar lamelas corneanas pediculadas de espessura e diâmetros adequados em olhos porcinos.


Asunto(s)
Humanos , Animales , Sustancia Propia/cirugía , Queratomileusis por Láser In Situ/instrumentación , Colgajos Quirúrgicos , Estudios Prospectivos , Reproducibilidad de los Resultados , Porcinos
9.
Arq. bras. oftalmol ; 68(6): 769-772, nov.-dez. 2005. tab, graf
Artículo en Portugués | LILACS | ID: lil-420184

RESUMEN

OBJETIVO: Verificar a ocorrência de movimentos torcionais do globo ocular no momento da cirurgia refrativa em pacientes astigmatas e suas possíveis conseqüências no resultado da cirurgia. MÉTODOS: Estudo prospectivo de 49 olhos de 40 pacientes atendidos no Hospital de Olhos do Paraná, portadores de astigmatismo, e que seriam submetidos à cirurgia refrativa. A técnica cirúrgica utilizada em todos os pacientes foi o LASIK. Os pacientes foram divididos em dois grupos, de acordo com o poder do astigmatismo, que variou no primeiro grupo 0,25 a 2,00D; e no segundo grupo de 2,25 a 6,00D. Todos os pacientes foram examinados para avaliar a ocorrência de torção do globo ocular no momento da cirurgia, e com base nestes dados foi corrigido o eixo do tratamento por meio de programa específico do aparelho de laser. Os resultados dos dois grupos foram analisados e comparados estatisticamente. Os resultados foram relacionados com os dados existentes sobre influência da variação do eixo do tratamento com o resultado da cirurgia. RESULTADOS: Observou-se torção média de 3,5°+/- no grupo A; e de 4,5°+/- no grupo B. Não houve diferença estatística significativa entre os grupos. CONCLUSÕES: Os movimentos torcionais ocorrem de forma significativa em quase todos os pacientes submetidos à cirurgia refrativa e portanto, devem ser sempre corrigidos para se evitar redução na eficiência do tratamento. Isto é especialmente importante nos casos de cirurgia personalizada.


Asunto(s)
Humanos , Masculino , Femenino , Astigmatismo , Movimientos Oculares/fisiología , Queratomileusis por Láser In Situ/instrumentación , Estudios Prospectivos , Distribución por Sexo , Anomalía Torsional
10.
Arch. chil. oftalmol ; 62(1/2): 87-100, 2005. tab, graf
Artículo en Español | LILACS | ID: lil-435480

RESUMEN

Objetivos: Evaluar las diferencias en la inducción de aberraciones de alto orden, coma, trefoil, aberración esférica y astigmatismo irregular entre pacientes operados con Lasik y Lasek, con ablación personalizada y con ablación convencional. Diseño: Retrospectivo. Participantes: 78 ojos pertenecientes a 51 pacientes, 31 mujeres y 20 hombres, miopes hasta 8 dioptrías, hipermétropes hasta 5 dioptrías, astigmatismo hasta 3 dioptrías. Cirugía: Se utilizó el láser Cx-5000 de Nidek; el programa Final- Fit versión 1.05 para la cirugía personalizada: el queratómetro MK_2000 de corte nasal, para la preparación del flap en el Lasik. La cirugía Lasek se practicó con alcohol absoluto al 18 por ciento con un máximo de 40 seg. Mediciones: Se seleccionaron retrospectivamente las topografías y aberrometrías obtenidas en el Nidek OPD-Scan. Los valores de Coma, Trefoil, Astigmatismo de Alto Orden, y Aberración esférica fueron tabulados. Se utilizó la prueba de Chi-Cuadrado para determinar la normalidad de los datos y la prueba de Fisher para determinar el nivel de significancia. Resultados: Las aberraciones de alto orden aumentaron significativamente con el Lasik convencional. Las aberraciones disminuyeron con el Lasek personalizado. Las aberraciones tipo coma aumentan con el Lasik personalizado, más que con las otras técnicas quirúrgicas. Conclusiones: Las aberraciones de alto orden sufren un menor aumento con la técnica de Lasek y ablación personalizado al usar el equipo quirúrgico de Nidek. Existe una tendencia a inducir coma al utilizar Lasik y ablación personalizada con este sistema.


Asunto(s)
Humanos , Masculino , Adulto , Femenino , Persona de Mediana Edad , Interpretación Estadística de Datos , Errores de Refracción/cirugía , Errores de Refracción/etiología , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/instrumentación , Distribución por Edad , Distribución de Chi-Cuadrado , Terapia por Láser/efectos adversos , Terapia por Láser/métodos , Complicaciones Posoperatorias/epidemiología , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos , Procedimientos Quirúrgicos Oftalmológicos/estadística & datos numéricos , Estudios Retrospectivos , Distribución por Sexo , Topografía de la Córnea/estadística & datos numéricos
11.
Arch. chil. oftalmol ; 58(1/2): 57-61, 2001. tab, graf
Artículo en Español | LILACS | ID: lil-388200

RESUMEN

Presentamos un estudio retrospectivos de 133 casos de LASIK miópico operados con el equipo VISX S2, con el objeto de obtener un nomograma ajustado a las características propias del equipo, Los pacientes fueron separados en dos grupos: bajas esferas con cilindros altos, y esferas mayores que los cilindros. Se pudo concluir, en forma preliminar, que: En el grupo 1 (cilindros mayor que esfera) la tendencia fue a la subcorrección cilíndrica. La corrección de cilindros altos no se acompañó de sobrecorrección esférica significativa. Los resultados refractivos en el grupo 2 (altas esferas, cilindros bajos) presentaron una distribución de tipo normal, con equilibrio entre la hipo e hipercorrección. La sobrecorrección severa que requirió retratamiento, mayor de 1 Diopatría, sólo alcanzó al 1 por ciento, siendo inferior a lo esperado. Es necesario mejorar el registro y seguimiento de los casos...


Asunto(s)
Queratomileusis por Láser In Situ/estadística & datos numéricos , Queratomileusis por Láser In Situ/instrumentación , Estudios Retrospectivos
12.
Rev. Fac. Cienc. Méd. (Córdoba) ; 57(1): 89-93, 2000. tab
Artículo en Español | LILACS | ID: lil-279412

RESUMEN

Objetivo: Describir un modo eficiente y predecible para realizar nomogramas personalizados con LASIK (Laser-assisted-in situ keratomileusis) aprovechando las ventajas de la cirugía bilateral. Métodos: Se describe una técnica para desarrollar nomograms para LASIK con un ejemplo para mostrarla. Para evaluar un cambio realizado en el software en nuestra unidad LaserSight excimer se estudiaron 16 pacientes consecutivos, operados bilateralmente por el mismo cirujano, dentro de un entorno clínico quirúrgico similar, clasificando el ojo derecho (OD) con un nuevo patrón de ablación (quemaduras randomizadas), y el ojo izquierdo (OS) comparándolo con el patrón anterior al cambio (quemaduras secuenciales superpuestas). De esta manera la única variable en el grupo estadístico, es el patrón diferente de ablacion para cada ojo. Los resultados refractivos finales fueron evaluados estadísticamente con el test "T" y Anova de 2 vías a las 4 semanas y 6 meses. Resultados: Preoperatoriamente, los datos refractivos mostraron una esfera media en OD de -10.917 ñ1.749, y en OS de -10.890 ñ1.717, p

Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Errores de Refracción/cirugía , Queratomileusis por Láser In Situ/instrumentación , Programas Informáticos/normas , Análisis de Varianza , Estudios de Seguimiento , Queratomileusis por Láser In Situ/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA